| Measuring Principle: |
Keypad: |
| Transit time difference |
18 Key with tactile
action |
| Pipe Size: |
Response
Time: |
| SS
Type : 15 mm ~ 100 mm (1/2" ~ 4") |
Less than 1 second |
| MS
Type : 50 mm ~ 700 mm (2" ~ 28") |
Flow
Velocity: |
| M
Type : 50 mm ~ 700 mm (2" ~ 28") |
0.01 ~ +/- 32 m/s |
| L
Type : 300 mm ~ 6000 mm (12" ~ 240") |
Resolution: |
| Pipe Material: |
0.0001 m/s |
| Cast
Iron, Stainless Steel, Ductile Iron |
Ambient
Temperature: |
| Copper, PVC, Aluminum, Asbestos |
|
| Fiberglass... etc |
Ambient
Humidity: |
| Liner Material: |
90% RH or Less |
| Tar
Epoxy, Rubber, Mortar, Polypropylene, |
Built-in
Battery: |
| Polystyrol, Polystyrene, Polyester, Ebonite, |
Ni-MH Battery |
| Polyethylene, Teflon... etc |
Operation
Time: |
| Display: |
> 10 Hours |
| 4
Line LCD with illumination |
Charger: |
| Flowrate |
90 ~ 260Vac 50/60 Hz, 8-12 Hr
charging |
| 5
digit with decimal point |
Data
Storage: |
| Totalizer |
Operation parameters and
totalizer |
| 8
digit, Forward, Reverse & Net values |
figures are stored by EEPROM for
more |
| Engineer Unit |
than 10 years |
| M3,
Liter, US Gallon, Imperial Gallon, |
Data Logger: |
| Million Gallon, Cubic Feet, US Barrels, |
Limitless overwriting in 64
columns |
| Imperial Barrels, Oil Barrel |
(Flowrate, totalizer, time, date included) |
| Time Unit |
Alarm: |
| Second, Minute, Hour, Day |
High/Low with
buzzer |
| Other |
Power
Consumption: |
| Velocity, Date, Time, Signal condition |
Less than 2W |
| Accuracy: |
Dimensions: |
| +/-
1% ~ +/- 2% of reading (0.5 ~ 30 m/s) |
200 * 92 * 32 mm |
| +/-
0.5% of reading (Online calibration) |
Weight: |
| Repeatability: |
0.54 Kg |
| +/-0.2% of reading |
Protection
Class: |
|
Converter |
|
IP65 |
|
Sensor |
|
IP68 (Submersible) |